Order Helpline 01752 692 206
Order Helpline 01752 692 206

Novia VC8 Reflective Air Leakage Barrier & Vapour Check - 50m x 1.5m

Code:
NOVIA VC8
Brand:

This advanced membrane, Novia VC8 Reflective, is designed to function as a reflective and airtight vapour check and convection barrier with an Sd value appropriate for insulated structures such as walls, roofs and floors in timber-framed dwellings. Unlike traditional reflectiv...Read More

£120.00 Incl. VAT
Oops! Please select from the options
Est. Delivery: 1-2 Working Days
Shipping costs displayed in basket.
We can let you know when this product is back in stock.

This product is proving to be very popular and has unfortunately sold out.

Enter your email below and we'll notify you as soon as this product is back in stock:

For delivery Tuesday, Apr 23rd - order in:
days hrs mins secs
Subject to stock availability, if products on a 24 hours service are ordered alongside products NOT on a 24 hours service, this may delay your whole order.
View Transport Policy

All delivery charges are included in the final shopping basket and are dependent on the products Scottish Highlands & the Islands where additional shipping charges will apply.

Please note that not all products will incur an additional delivery charge to the Scottish Highlands & the Islands – this is based on the costs from the manufacturer, distributor or courier providing shipping on our behalf. If your delivery address is in the Scottish Highlands and Islands, a member of our helpline team will contact you prior to processing your order should an additional delivery charge apply.

While we make every effort to ensure orders are delivered by the date required, we cannot guarantee availability from the manufacturer or the manufacturer's delivery schedules.

Any variation to web delivery date given will be advised to you by email or telephone. If we are unable to make delivery because access is not possible, we reserve the right to make a failed delivery charge.

Create a wishlist

"No problems delivered as ordered."

Ken A

Description

This advanced membrane, Novia VC8 Reflective, is designed to function as a reflective and airtight vapour check and convection barrier with an Sd value appropriate for insulated structures such as walls, roofs and floors in timber-framed dwellings.

Unlike traditional reflective vapour barriers with excessively high vapour resistances, Novia VC8 Reflective protects the building envelope from any damage and improves indoor air quality without suffocating the structure. This is due to its chosen Sd value of 8m.

Features & Benefits: Novia VC8 Reflective Air Leakage Barrier & Vapour Check - 50m x 1.5m

  • Roll size of 75m²
  • 50m length x 1.5m width x 0.4mm thickness
  • 77gsm weight
  • Temperature resistance from -40°C to +80°C
  • 84% reflectivity
  • 8m Sd-Value
  • Limits unwanted condensation within wall and ceiling structures
  • Manages water vapour diffusion
  • Reflective and airtight

CE Approved and compliant with CPR standard, this product delivers the key attributes of a reflective VCL, including improved ? values, interstitial water vapour condensation management and the prevention of unwanted air-leakage. Vapour Control Layers allow you to manage how naturally produced water vapour transitions through the building envelope as a result of general building use. Novia's VCL membranes work for numerous construction designs with specific solutions for all sorts of applications and needs.

Installation

  • To optimise performance, install VCLs on the interior (warm side) of walls, roofs, or insulated frames, and use Novia external breather membranes on the exterior (cold side). Ensure effective installation by using Novia tapes as part of a two-tape sealing system for all VCL products. Incorrect installation and tape usage can lead to condensation issues in finished buildings, as well as undesirable outcomes.
  • Achieve 100% sealing to the structure by using double-sided butyl tapes and either foil or BOPP lap tape for a professional installation. The wider the tape, the better the seal's strength and ease of installation. Choose a tape based on your specific application and budget. Novia recommends 30mm wide butyl tape and 60mm Metallised BOPP tape for standard VCL installations.

Standards & Certification

  • Reaction to fire: Class F to EN 13501-1
  • Certification: CE approved to EN 13984 and CPR complaint

Please note:

  • The use of Novia compatible butyl and foil sealing tapes are advised to ensure a complete barrier integrity throughout the entire life of the product. Novia VC8 should be used in combination with Novia breather membranes to provide an air-tight and vapour resistant system.

Dimensions

Length 50m Width 1.5m

Details

Permeability Vapour Barrier Roll Size 75m2 Range VC8

Downloads

There are no product downloads to show.

Questions & Answers

There are currently no questions for this product.

Reviews

loading...

Product Enquiry Form

Novia VC8 Reflective Air Leakage Barrier & Vapour Check - 50m x 1.5m

*Required Field