Order Helpline 01752 692 206

Multifoil Insulation H Control Hybrid by Actis - 6.25m x 1.6m (10m2)

Product Code:
IAH87001
Brand:
Est. Delivery: 1-2 Working Days
Shipping costs displayed in basket.
We can let you know when this product is back in stock.

This product is proving to be very popular and has unfortunately sold out.

Enter your email below and we'll notify you as soon as this product is back in stock:

Subject to stock availability, if products on a 24 hours service are ordered alongside products NOT on a 24 hours service, this may delay your whole order.

View Transport Policy

All delivery charges are included in the final shopping basket and are dependent on the products Scottish Highlands & the Islands where additional shipping charges will apply.

Please note that not all products will incur an additional delivery charge to the Scottish Highlands & the Islands – this is based on the costs from the manufacturer, distributor or courier providing shipping on our behalf. If your delivery address is in the Scottish Highlands and Islands, a member of our helpline team will contact you prior to processing your order should an additional delivery charge apply.

While we make every effort to ensure orders are delivered by the date required, we cannot guarantee availability from the manufacturer or the manufacturer's delivery schedules.

Any variation to web delivery date given will be advised to you by email or telephone. If we are unable to make delivery because access is not possible, we reserve the right to make a failed delivery charge.

£85.32 Incl. VAT
Oops! Please select from the options

Description

H Control Hybrid provides dual performance within a single product : a vapour control layer and insulation, allowing a reduction in the number of installation steps whilst reducing the thickness of the main insulation to achieve the same required U-Value. It can be used in conjunction with any type of insulation.

H Control Hybrid is a reflective vapour control layer with a built-in thermal performance for use on the warm side of any insulation material, behind the internal finish in roofs, walls and ceilings.

Features & Benefits: Multifoil Insulation H Control Hybrid by Actis - 6.25m x 1.6m (10m2)

  • Quick and easy to install
  • Provides dual properties within a single product: insulation product with a built-in vapour control function
  • Exceptional thermal performance
  • Does not compact over time
  • Flexible - thermal bridging is virtually eliminated
  • No irritating fibres
  • Lightweight; easy to carry, transport and store
  • Core R value: 1.90K/W
  • Fire resistance: Class F
  • Air permeability: air tight
  • Watertightness: Watertight
  • Core R value: 1.90K/W
  • Fire resistance: Class F
  • Air permeability: air tight
  • Watertightness: Watertight

Dimensions

Length 6250mm Thickness 45mm Width 1.6m
1600mm

Details

Application Below Rafter
Ceiling
Internal Walls
Product Type Roll Fire Performance Class F Material Multifoil
Coverage 10m2 Roll Size 10m2 Weight 950gsm Range Actis

Questions & Answers

Question:

i I need a u value of 0.18 for my loft conversion but my rafters are only 75mm can I use a PIR board with this product wondering if I can keep thickness of the installation to a minimum

Answer:

This product can be used in conjunction with others such as PIR board, however this is simply a vapour control layer designed to go underneath your rafters instead of between them. 

Have a question about this product?

Reviews

4.5 / 5 2 reviews
pwhipp
21st February
Great Product. Actually performs as it should
Scott
7th April 2020
Effective insulation but I have yet to find a fool-proof way of screwing counterbattens onto this. You can't pre-drill because the fibre in the insulation wraps round the drill bit, melts and snaps it. I had to use self-drilling woodscrews but these were even worse. And once the insulation melts onto the screw, you can't back it back out of the batten. Best way I found is to drill the screw until you see it pulling at the insulation behind the batten you are fixing and then belting it a few times with a hammer to drive it through. Then finish screwing. It is possible to get the screw straight in if you can apply a lot of clamping pressure against the batten but that's not always easy when you are installing at heights. Even the hammer method is only effective say 75% of the time. Keeps the room nice and warm, a huge difference but I reckon half of that is heat from The Rage.
Sorry, there was a problem loading the reviews. Please try again.

Products We Recommend

loading...

Product Enquiry Form

Multifoil Insulation H Control Hybrid by Actis - 6.25m x 1.6m (10m2)

*Required Field

Would you like to empty your basket?

Yes No

Sorry

It seems you are running an older version of Internet Explorer. Our site does not support these old browsers as they do not house the technology that allows our site to be safe and secure.

If you wish to access our site please either upgrade your browser or download an alternative.